#include <AtNuFitModule.h>
Inheritance diagram for AtNuFitModule:

Public Member Functions | |
| AtNuFitModule () | |
| ~AtNuFitModule () | |
| void | BeginJob () |
| JobCResult | Reco (MomNavigator *mom) |
| JobCResult | Ana (const MomNavigator *mom) |
| const Registry & | DefaultConfig () const |
| void | Config (const Registry &r) |
| void | HandleCommand (JobCommand *command) |
| void | EndJob () |
Private Attributes | |
| TString | fListIn |
| TString | fListOut |
|
|
Definition at line 31 of file AtNuFitModule.cxx. 00031 : 00032 fListIn("CandTrackListHandle"), 00033 fListOut("CandFitTrackAtNuListHandle") 00034 { 00035 00036 }
|
|
|
Definition at line 38 of file AtNuFitModule.cxx. 00039 {
00040
00041 }
|
|
|
Implement this for read only access to the MomNavigator Reimplemented from JobCModule. Definition at line 109 of file AtNuFitModule.cxx. 00110 {
00111
00112 JobCResult result(JobCResult::kPassed);
00113
00114
00115 return result;
00116
00117 }
|
|
|
Implement for notification of begin of job Reimplemented from JobCModule. Definition at line 43 of file AtNuFitModule.cxx. References MSG. 00044 {
00045
00046 MSG("AtNuFitModule", Msg::kInfo) << " *** AtNuFitModule::BeginJob() *** " << endl;
00047
00048 /*
00049 AlgFactory &af = AlgFactory::GetInstance();
00050 af.Register("AlgFitTrackAtNuList", "default", "libAtNuReco.so", "AlgConfig");
00051 af.Register("AlgFitTrackAtNu", "default", "libAtNuReco.so", "AlgConfig");
00052 */
00053 }
|
|
|
Return the actual configuration. If your module directly pulls its configuration from the fConfig Registry, you don't need to override this. Override if you have local config variables. Reimplemented from JobCModule. Definition at line 144 of file AtNuFitModule.cxx. References fListIn, fListOut, Registry::Get(), AlgHandle::GetAlgConfig(), AlgFactory::GetAlgHandle(), AlgFactory::GetInstance(), Registry::LockValues(), MSG, Registry::Set(), and Registry::UnLockValues(). 00145 {
00146
00147 MSG("AtNuFitModule", Msg::kInfo) << " *** AtNuFitModule::Config() *** " << endl;
00148
00149 Int_t tmpint=0;
00150 const char* tmpchar = 0;
00151 if(r.Get("ListIn",tmpchar)) fListIn = tmpchar;
00152 if(r.Get("ListOut",tmpchar)) fListOut = tmpchar;
00153 MSG("AtNuFitModule", Msg::kInfo) << " ... input: " << fListIn.Data() << endl;
00154 MSG("AtNuFitModule", Msg::kInfo) << " ... output: " << fListOut.Data() << endl;
00155
00156 AlgFactory &af = AlgFactory::GetInstance();
00157
00158 AlgHandle ah_atnu = af.GetAlgHandle("AlgFitTrackAtNu","default");
00159 AlgConfig &ac_atnu = ah_atnu.GetAlgConfig();
00160 ac_atnu.UnLockValues();
00161 if(r.Get("BFieldMap",tmpint)) ac_atnu.Set("BFieldMap",tmpint);
00162 ac_atnu.LockValues();
00163
00164
00165 return;
00166 }
|
|
|
Get the default configuration registry. This should normally be overridden. One useful idiom is to implement it like: const Registry& MyModule::DefaultConfig() const { static Registry cfg; // never is destroyed if (cfg.Size()) return cfg; // already filled it // set defaults: cfg.Set("TheAnswer",42); cfg.Set("Units","unknown"); return cfg; } Reimplemented from JobCModule. Definition at line 119 of file AtNuFitModule.cxx. References fListIn, fListOut, AlgHandle::GetAlgConfig(), AlgFactory::GetAlgHandle(), AlgFactory::GetInstance(), Registry::LockValues(), MSG, AlgFactory::Register(), Registry::Set(), and Registry::UnLockValues(). 00120 {
00121
00122 MSG("AtNuFitModule", Msg::kInfo) << " *** AtNuFitModule::DefaultConfig() *** " << endl;
00123
00124 static Registry r;
00125 r.SetName("AtNuFitModule.config.default");
00126 r.UnLockValues();
00127 r.Set("ListIn",fListIn.Data());
00128 r.Set("ListOut",fListOut.Data());
00129 r.Set("BFieldMap",201);
00130 r.LockValues();
00131
00132 AlgFactory &af = AlgFactory::GetInstance();
00133
00134 af.Register("AlgFitTrackAtNu", "default");
00135 AlgHandle ah_atnu = af.GetAlgHandle("AlgFitTrackAtNu","default");
00136 AlgConfig &ac_atnu = ah_atnu.GetAlgConfig();
00137 ac_atnu.UnLockValues();
00138 ac_atnu.Set("BFieldMap",201);
00139 ac_atnu.LockValues();
00140
00141 return r;
00142 }
|
|
|
Implement for notification of end of job Reimplemented from JobCModule. Definition at line 177 of file AtNuFitModule.cxx. 00178 {
00179
00180 }
|
|
|
Implement to handle a JobCommand Reimplemented from JobCModule. Definition at line 168 of file AtNuFitModule.cxx. References JobCommand::PopCmd(), and JobCommand::PopOpt(). 00169 {
00170 TString cmd = command->PopCmd();
00171 if(cmd=="Set"){
00172 TString opt = command->PopOpt();
00173
00174 }
00175 }
|
|
|
Implement this for read-write access to the MomNavigator Reimplemented from JobCModule. Definition at line 55 of file AtNuFitModule.cxx. References CandRecord::FindCandHandle(), fListIn, fListOut, AlgFactory::GetAlgHandle(), MomNavigator::GetFragment(), AlgFactory::GetInstance(), CandHandle::GetName(), CandFitTrackAtNuList::MakeCandidate(), MSG, CandRecord::SecureCandHandle(), JobCResult::SetAOK(), CandContext::SetCandRecord(), CandFitTrackAtNuListHandle::SetCPUTime(), CandContext::SetDataIn(), JobCResult::SetFailed(), CandHandle::SetName(), and CandHandle::SetTitle(). 00056 {
00057
00058 // AtNuFitModule::Reco()
00059 MSG("AtNuFitModule", Msg::kInfo) << " *** AtNuFitModule::Reco() *** " << endl;
00060 JobCResult result(JobCResult::kPassed);
00061
00062 // Start Clock
00063 struct timeval tpbefore;
00064 gettimeofday(&tpbefore,0);
00065
00066 // Get CandRecord
00067 CandRecord *candrec = dynamic_cast<CandRecord *> (mom->GetFragment("CandRecord", "PrimaryCandidateRecord"));
00068 if(!candrec){
00069 MSG("AtNuFitModule", Msg::kWarning) << " Failed to Fit CandRecord " << endl;
00070 return result.SetFailed();
00071 }
00072
00073 // Get CandTrackListHandle
00074 CandTrackListHandle* track_list = dynamic_cast<CandTrackListHandle*>(candrec->FindCandHandle("CandTrackListHandle",fListIn.Data()));
00075 if(!track_list){
00076 MSG("AtNuFitModule", Msg::kWarning) << " Failed to Find " << fListIn.Data() << endl;
00077 return result.SetAOK();
00078 }
00079
00080 // Make CandFitTrackAtNuHandle
00081 MSG("AtNuFitModule", Msg::kDebug) << " Make CandFitTrackAtNuHandle " << endl;
00082
00083 AlgFactory &af = AlgFactory::GetInstance();
00084 AlgHandle ah_atnu = af.GetAlgHandle("AlgFitTrackAtNuList", "default");
00085 CandContext cx_atnu(this, mom);
00086 cx_atnu.SetCandRecord(candrec);
00087 cx_atnu.SetDataIn(track_list);
00088
00089 CandFitTrackAtNuListHandle candfittrack = CandFitTrackAtNuList::MakeCandidate(ah_atnu, cx_atnu);
00090 candfittrack.SetName(fListOut.Data());
00091 candfittrack.SetTitle(TString("Created by AtNuFitModule from ").Append(track_list->GetName()));
00092
00093 // Stop Clock
00094 struct timeval tpafter;
00095 gettimeofday(&tpafter,0);
00096
00097 Double_t dtime;
00098 dtime = 1000.0*(tpafter.tv_sec-tpbefore.tv_sec)+0.001*(tpafter.tv_usec-tpbefore.tv_usec);
00099 candfittrack.SetCPUTime(dtime);
00100
00101 candrec->SecureCandHandle(candfittrack);
00102
00103 MSG("AtNuFitModule", Msg::kInfo) << " *** AtNuFitModule::Reco() FINISHED *** " << endl;
00104
00105 return result;
00106
00107 }
|
|
|
Definition at line 26 of file AtNuFitModule.h. Referenced by Config(), DefaultConfig(), and Reco(). |
|
|
Definition at line 27 of file AtNuFitModule.h. Referenced by Config(), DefaultConfig(), and Reco(). |
1.3.9.1